热电偶组件基于塞贝克效应工作:两种不同金属(铬镍和铝镍)在测量端连接,产生的电压与热端(浸入熔融金属)和冷端(参考点)之间的温差成正比。该电压通过延长线传输至温度控制器或监测系统,转换为温度读数。保护套管将传感器与熔融金属隔离,陶瓷绝缘珠防止电气短路。接线盒容纳电气端子,并提供密封接口(IP65),防止灰尘和水喷射。
| 参数 | 典型区间 | 选型说明与越界后果 |
|---|---|---|
| 温度范围 | 0–1300 °C | Type K thermocouple; continuous operation up to 1100°CIEC 60584 |
| 精度等级 | Class 1 | ±1.5°C or ±0.4% of reading, whichever is greaterIEC 60584 |
| 护套直径 | 6–12 mm | Larger diameter for higher mechanical strength |
| 插入长度 | 300–1500 mm | Custom lengths available |
| 响应时间 | 2–10 s | Time to reach 63.2% of step change |
| 绝缘电阻 | ≥100 MΩ | At 500 V DC, ambient temperatureIEC 60751 |
| 工作压力 | 1.0–1.6 MPa | |
| 护套材料 | 310S | Stainless steel for high temperature oxidation resistanceASTM A312 |
| 热电偶类型 | K | Nickel-chromium / Nickel-aluminumIEC 60584 |
| 接线盒 | IP65 | Dust-tight and protected against water jetsIEC 60529 |
| 过程连接 | G1/2 | Thread size; other sizes availableISO 228-1 |
| 重量 | 0.5–2.5 kg | Depends on length and head type |
区间为行业参考值,供询价时圈定范围用,不构成供应商承诺。下单前请向法人制造商核实每一项数值与标准。
诱因 → 失效模式 → 工程缓解
| pressure: | 标准组件为大气压至10巴(145 psi),特殊设计可承受更高压力 |
| flow rate: | 不适用 |
| temperature: | 短期浸入最高1800°C(3272°F),连续使用通常为1200-1600°C,具体取决于套管材料 |
不是客户评论,也不是实时热度。以下维度用于前期 RFQ 准备和供应商评估。
这些分值是采购评估维度示例,不代表真实客户评分、具体国家买家反馈或实时询盘。
温度范围为0–1300°C,连续运行最高1100°C。精度等级为IEC 60584规定的1级。请务必与制造商确认具体型号的范围。
热电偶丝为K型(铬镍-铝镍),保护套管为Inconel 600,接线盒为不锈钢(310S级),并使用陶瓷绝缘珠。这些材料具有耐高温和机械强度。
响应时间为2–10秒,定义为达到阶跃变化63.2%的时间。实际响应时间可能因安装和工艺条件而异。
相关标准包括IEC 60584(热电偶精度)、IEC 60751(绝缘电阻)和IEC 60529(IP65接线盒)。这些是参考标准,合规性需与制造商确认。
CNFX 是开放目录,不是交易平台或采购代理。工厂资料和表单用于帮助你准备直接沟通。
CNFX 制造商资料、技术分类、公开产品信息和持续合理性检查。
说明目标数量、应用场景、交期和关键技术要求,用于准备 RFQ 或供应商评估。