磁性模块利用基于变压器的隔离原理工作,其中初级和次级绕组磁耦合但电气隔离。它包含脉冲变压器,用于传输以太网信号,同时阻断直流分量和共模噪声。模块通常包含共模扼流圈,通过对共模信号产生阻抗来抑制电磁干扰,同时允许差模数据信号通过。这种组合提供了以太网通信协议所需的电流隔离、噪声滤波和阻抗匹配。
| 参数 | 典型区间 | 选型说明与越界后果 |
|---|---|---|
| 工作温度范围 | -40–85 °C | Exceeding range may degrade magnetic properties and insulation. |
| 隔离电压 | 1500 Vrms | Minimum for safety isolation per standard.IEC 60950 |
| 插入损耗 | -1.0–-0.5 dB | Lower absolute value indicates better signal integrity. |
| 回波损耗 | -18–-10 dB | Higher absolute value indicates better impedance matching. |
| 共模抑制比 | -40–-30 dB | Higher absolute value indicates better noise filtering. |
| 电感量 | 350–500 µH | Measured at 100 kHz, 0.1 Vrms. |
| 直流电阻 | 0.5–1.5 Ω | Per winding; lower is better for power efficiency. |
| 匝数比 | 1:1 | Typical for 10/100/1000BASE-T. |
| 工作湿度范围 | 20–85 %RH | Non-condensing; high humidity may cause corrosion. |
| 存储温度范围 | -40–125 °C | Exceeding may cause permanent damage. |
| 封装尺寸 | 9.0–12.0 mm | Length or width; typical for SMD packages. |
| 重量 | 0.5–2.0 g | Affects handling and PCB mechanical stress. |
区间为行业参考值,供询价时圈定范围用,不构成供应商承诺。下单前请向法人制造商核实每一项数值与标准。
诱因 → 失效模式 → 工程缓解
| pressure: | 不适用(固态组件) |
| other spec: | 工作频率:10/100/1000 Mbps 以太网标准 |
| temperature: | -40°C 至 +85°C |
不是客户评论,也不是实时热度。以下维度用于前期 RFQ 准备和供应商评估。
这些分值是采购评估维度示例,不代表真实客户评分、具体国家买家反馈或实时询盘。
它提供电气隔离、阻抗匹配和噪声滤波,以确保信号完整性和可靠的网络连接。
典型参考值为1500 Vrms,符合IEC 60950,但必须与制造商确认具体型号的额定值。
常用材料包括铁氧体磁芯、铜线、环氧树脂和塑料外壳。
始终检查数据表,并与法定制造商或供应商确认型号特定值和标准。
CNFX 是开放目录,不是交易平台或采购代理。工厂资料和表单用于帮助你准备直接沟通。
CNFX 制造商资料、技术分类、公开产品信息和持续合理性检查。
说明目标数量、应用场景、交期和关键技术要求,用于准备 RFQ 或供应商评估。