当接地验证传感器检测到正确的接地条件时,控制电路为继电器线圈通电,产生磁场,使衔铁移动,闭合常开触点。这完成了输出电路,允许电流流向连接的设备。当检测到接地故障时,线圈断电,触点返回常开位置,中断输出电路。
| 参数 | 典型区间 | 选型说明与越界后果 |
|---|---|---|
| 触点额定值 | 5–30 A | Maximum switching current at resistive loadIEC 61810 |
| 线圈电压 | 12–24 V DC | Nominal coil voltage range |
| 线圈功耗 | 0.9–1.2 W | At nominal coil voltage |
| 接触电阻 | ≤50 mΩ | Initial value at 6 V DC, 1 AIEC 61810 |
| 绝缘电阻 | ≥100 MΩ | Between coil and contacts at 500 V DCIEC 60255 |
| 介电强度 | 1500–2500 V AC | Between coil and contacts for 1 minuteIEC 60255 |
| 工作温度 | -40–85 °C | Ambient temperature rangeIEC 60068-2 |
| 机械寿命 | ≥10^7 操作 | No load switchingIEC 61810 |
| 电寿命 | ≥10^5 操作 | At rated resistive loadIEC 61810 |
| 响应时间 | ≤20 ms | From coil energization to contact closure |
| 释放时间 | ≤10 ms | From coil de-energization to contact opening |
| 防护等级 | IP54–IP65 | Protection against dust and waterIEC 60529 |
| 重量 | 30–50 g | Typical for PCB mount relay |
区间为行业参考值,供询价时圈定范围用,不构成供应商承诺。下单前请向法人制造商核实每一项数值与标准。
诱因 → 失效模式 → 工程缓解
该产品或部件会出现在以下工业系统、设备或上级产品中。
| current: | 最大10A电阻性负载 |
| voltage: | 最高250V交流/直流 |
| temperature: | -40°C 至 +85°C |
| switching frequency: | 最高1 Hz |
| insulation resistance: | >100 MΩ @ 500V 直流 |
不是客户评论,也不是实时热度。以下维度用于前期 RFQ 准备和供应商评估。
这些分值是采购评估维度示例,不代表真实客户评分、具体国家买家反馈或实时询盘。
输出继电器作为最终控制元件,接收传感器检测电路处理后的信号,并根据是否验证到正确接地或检测到故障,打开或关闭其触点,以控制外部电路、报警或安全系统。
继电器在阻性负载下的触点额定值为5–30 A,线圈电压为12–24 V DC,线圈功耗为0.9–1.2 W。接触电阻在6 V DC、1 A条件下初始值≤50 mΩ。绝缘电阻在500 V DC下≥100 MΩ,介电强度为1500–2500 V AC(持续1分钟)。
继电器的工作环境温度范围为-40至85 °C,防护等级为IP54–IP65,可防尘和防水。这些数值是参考范围,应针对具体型号进行确认。
机械寿命≥10^7次(无负载),电气寿命≥10^5次(在额定阻性负载下)。这些数据基于IEC 61810,实际应用中的寿命应咨询制造商。
CNFX 是开放目录,不是交易平台或采购代理。工厂资料和表单用于帮助你准备直接沟通。
CNFX 制造商资料、技术分类、公开产品信息和持续合理性检查。
说明目标数量、应用场景、交期和关键技术要求,用于准备 RFQ 或供应商评估。