Secondary winding is the output coil in a current transformer that produces a reduced current proportional to the primary current for measurement and protection.

技术定义与适配语境
典型 次级绕组 会按材料、尺寸公差、适配关系和失效风险在 电气设备制造 中评估。

The secondary winding in a current transformer is a precisely wound coil of insulated copper wire that forms the output circuit. It is designed to produce a standardized secondary current (typically 1A or 5A) that is directly proportional to the primary current flowing through the transformer's core. This component enables safe measurement, monitoring, and protection of high-current systems by isolating measurement circuits from high-voltage primary circuits.

组件规格

定义
The secondary winding in a current transformer is a precisely wound coil of insulated copper wire that forms the output circuit. It is designed to produce a standardized secondary current (typically 1A or 5A) that is directly proportional to the primary current flowing through the transformer's core. This component enables safe measurement, monitoring, and protection of high-current systems by isolating measurement circuits from high-voltage primary circuits.
工作原理
Operates on electromagnetic induction principle where alternating current in the primary winding creates a varying magnetic flux in the core, which induces a proportional current in the secondary winding according to the transformer's turns ratio (Np:Ns).
材料
High-purity electrolytic copper wire (99.9% Cu) with Class F (155°C) or higher thermal class insulationtypically polyimide or polyester film insulation. Core material is usually grain-oriented silicon steel or nanocrystalline alloy.
Burden
2.5-30 VA
Frequency
50/60 Hz
Turns Ratio
Typically 100:1 to 5000:1
Accuracy Class
0.2, 0.5, 1, 3, 5
Thermal Rating
1.2 x rated current continuous
Insulation Class
Class F (155°C) minimum
Rated Secondary Current
1A or 5A
标准
IEC 61869-2IEEE C57.13ANSI C57.13GB/T 20840.2

行业分类与别名

次级绕组 的常用贸易名称、技术标识和检索关键词。

上级产品

该组件会出现在以下整机或工业产品中。

FMEA · 风险与缓解

诱因 → 失效模式 → 工程缓解

Open secondary circuit during operation->Dangerously high induced voltage, insulation breakdown, arcing->Always short-circuit secondary terminals before disconnecting, use shorting switches, implement protective circuits
Excessive primary current beyond rating->Core saturation, waveform distortion, measurement inaccuracy->Select proper accuracy limit factor (ALF), use saturation-resistant core materials, implement overcurrent protection
Poor insulation quality or contamination->Insulation breakdown, short circuits, equipment damage->Use high-temperature insulation materials, implement regular insulation resistance testing, maintain clean environment

工业生态与工程逻辑

0
Open-circuit voltage hazards
1
Insulation breakdown
2
Saturation at high currents
3
Thermal overload
4
Incorrect polarity connection

合规与检测

tolerance
±0.2% to ±5% depending on accuracy class at rated current and burden
test method
Ratio error test, phase displacement test, insulation resistance test, dielectric strength test, burden verification test

制造该组件的工厂

来自 CNFX 组件能力表的相关制造商资料。

制造商列表用于前期研究和供应商能力理解,不代表认证、排名或交易担保。

采购评估维度

不是客户评论,也不是实时热度。以下维度用于前期 RFQ 准备和供应商评估。

技术文档
4/5
制造能力
4/5
可检验性
5/5
供应商透明度
3/5

这些分值是采购评估维度示例,不代表真实客户评分、具体国家买家反馈或实时询盘。

相关组件

常见问题

What happens if the secondary winding of a current transformer is open-circuited?

Open-circuiting the secondary winding creates dangerously high voltages that can damage insulation, cause arcing, and pose serious safety hazards. Current transformers must never operate with an open secondary circuit.

What is the difference between 1A and 5A secondary windings?

1A secondary windings have more turns and are used for long-distance transmission with lower power loss, while 5A secondary windings have fewer turns and are common for local measurement with standard instruments.

How is secondary winding accuracy class determined?

Accuracy class (0.2, 0.5, 1, etc.) indicates the maximum percentage error at rated current. Class 0.2 has ±0.2% error for metering, while Class 5 has ±5% error for protection applications.

我可以直接联系工厂吗?

CNFX 是开放目录,不是交易平台或采购代理。工厂资料和表单用于帮助你准备直接沟通。

CNFX Industrial Component Index · 电气设备制造

数据基础

CNFX 制造商资料、技术分类、公开产品信息和持续合理性检查。

初步技术归类
本页用于结构化准备研究、RFQ 和供应商评估,不替代买方自己的供应商资质审查、标准核验和技术批准。

请求制造能力信息: 次级绕组

说明目标数量、应用场景、交期和关键技术要求,用于准备 RFQ 或供应商评估。

谢谢,信息已发送。
谢谢,信息已收到。

需要制造 次级绕组?

对比具备该组件加工或装配能力的制造商资料。

创建制造商档案 联系我们
上一个组件
桥接器/跳线
下一个组件
次级绕组骨架
URN:CNFX:ME:UNIT:SECONDARY_WINDING