热钢带通过一系列配备集管和喷嘴的冷却段。水以受控的层流射流形式喷射到钢带的上表面和下表面。系统通过调节水流量、集管激活模式和钢带速度来调节冷却强度,以遵循预定的温度-时间曲线(冷却曲线),将奥氏体微观组织转变为目标相(如铁素体、珠光体、贝氏体)。
| 参数 | 典型区间 | 选型说明与越界后果 |
|---|---|---|
| 冷却水流量 | 500–2000 m³/h | Depends on strip thickness and speed |
| 冷却水温度 | 20–35 °C | Higher temperature reduces cooling efficiency |
| 工作压力 | 0.3–0.8 MPa | Below 0.3 MPa insufficient cooling |
| 冷却区长度 | 10–60 m | Longer zones allow slower cooling rates |
| 带钢厚度范围 | 1.0–25.4 mm | Thicker strips require higher flow rates |
| 带钢速度 | 60–300 m/min | Affects cooling time and uniformity |
| 冷却速率控制精度 | ±5 % | Critical for microstructure properties |
| 温度均匀性 | ±10 °C | Across strip width and length |
| 水过滤精度 | 50–200 µm | Prevents nozzle clogging |
| 喷嘴类型 | Laminar | Ensures uniform flow pattern |
| 制造材料 | SS304 | Corrosion resistant for water contactASTM A240 |
| 电力消耗 | 50–200 kW | Includes pumps and control system |
| 控制系统电压 | 380–480 V AC | Three-phase, 50/60 HzIEC 60038 |
| 防护等级 | IP54–IP65 | For electrical enclosuresIEC 60529 |
区间为行业参考值,供询价时圈定范围用,不构成供应商承诺。下单前请向法人制造商核实每一项数值与标准。
诱因 → 失效模式 → 工程缓解
| pressure: | 最大值: 10 巴 (145 psi) |
| flow rate: | 单喷嘴: 50-200 升/分钟 |
| temperature: | 入口: 600-900°C, 出口: 200-400°C |
不是客户评论,也不是实时热度。以下维度用于前期 RFQ 准备和供应商评估。
这些分值是采购评估维度示例,不代表真实客户评分、具体国家买家反馈或实时询盘。
参考范围为500–2000 m³/h,取决于钢带厚度和速度。请与制造商确认具体应用的确切值。
参考范围为0.3–0.8 MPa 作为验证标准。低于0.3 MPa可能导致冷却不足。请与供应商核实。
温度均匀性保持在钢带宽度和长度方向±10 °C以内,通过受控层流和集管激活实现。请与制造商确认。
集管/喷嘴使用不锈钢(SS304,ASTM A240),管道/框架使用碳钢,以及耐磨合金。请与供应商核实材料等级。
CNFX 是开放目录,不是交易平台或采购代理。工厂资料和表单用于帮助你准备直接沟通。
CNFX 制造商资料、技术分类、公开产品信息和持续合理性检查。
说明目标数量、应用场景、交期和关键技术要求,用于准备 RFQ 或供应商评估。