整流桥通过其二极管网络允许电流仅沿一个方向流动。在交流输入的正半周期,两个二极管导通,使电流以某一极性流过负载;在负半周期,另外两个二极管导通,保持通过负载的电流方向不变。此过程产生脉动直流输出,通常由电路中的电容器进行平滑。
| 参数 | 典型区间 | 选型说明与越界后果 |
|---|---|---|
| 额定输出电流 | 1–100 A | Continuous DC output current at specified case temperature |
| 峰值反向电压 | 50–1600 V | Maximum repetitive reverse voltage per diode |
| 正向压降 | 0.8–1.2 V | At rated current and 25°C junction temperature |
| 工作结温 | -40–150 °C | Exceeding may cause thermal runaway |
| 存储温度 | -55–150 °C | Non-operating condition |
| 介电强度 | 1500–2500 V AC | Between terminals and case for 1 minuteIEC 60947-1 |
| 绝缘电阻 | ≥100 MΩ | At 500 V DC between terminals and caseIEC 60947-1 |
| 浪涌电流能力 | 50–300 A | Non-repetitive peak current for 10 ms |
| 热阻(结到壳) | 0.5–5.0 K/W | Lower is better for heat dissipation |
| 安装扭矩 | 0.5–1.5 N·m | For screw mounting to heatsink |
| 重量 | 5–50 g | Depends on package type (e.g., DIP, SIP, GBPC) |
| 湿度范围 | 5–95 % RH | Non-condensingIEC 60068-2-78 |
区间为行业参考值,供询价时圈定范围用,不构成供应商承诺。下单前请向法人制造商核实每一项数值与标准。
诱因 → 失效模式 → 工程缓解
该产品或部件会出现在以下工业系统、设备或上级产品中。
| pressure: | 不适用 |
| flow rate: | 不适用 |
| temperature: | -40°C 至 +150°C(工作),-55°C 至 +175°C(存储) |
7 家企业把这个产品列在自己的产品线里。卡片上的公司数据摘自各家官网,每张卡都注明这条关系的依据来自哪里。
制造商列表用于前期研究和供应商能力理解,不代表认证、排名或交易担保。
不是客户评论,也不是实时热度。以下维度用于前期 RFQ 准备和供应商评估。
这些分值是采购评估维度示例,不代表真实客户评分、具体国家买家反馈或实时询盘。
整流桥利用二极管配置将交流电(AC)转换为直流电(DC)。它常用于电源和电池充电器,以提供单向电流。
典型应用包括电子设备电源、电池充电电路、直流电机驱动以及需要从交流电源获得直流电的工业设备。
考虑所需的直流输出电流和电压、输入交流电压、热条件和安装限制。根据电路要求验证额定输出电流、峰值反向电压和热阻等参数。
注意过热、异常噪音或输出电压降低。二极管故障可能导致整流不完整。定期检查连接,确保工作温度在指定范围内。
CNFX 是开放目录,不是交易平台或采购代理。工厂资料和表单用于帮助你准备直接沟通。
CNFX 制造商资料、技术分类、公开产品信息和持续合理性检查。
说明目标数量、应用场景、交期和关键技术要求,用于准备 RFQ 或供应商评估。