热式过载继电器使用双金属片或焊料锅,其发热与电机电流成比例。过大的电流导致双金属片弯曲或焊料熔化,机械释放锁扣使继电器脱扣。电子式过载继电器使用电流互感器或传感器测量电流,微处理器将测量值与编程的脱扣曲线(例如10、20、30级)和时间延迟进行比较,然后发送信号使输出触点脱扣。
| 参数 | 典型区间 | 选型说明与越界后果 |
|---|---|---|
| 额定工作电流 | 0.1–630 A | Select according to motor full-load current.IEC 60947-4-1 |
| 整定范围 | 0.1–630 A | Adjustable to match motor FLA.IEC 60947-4-1 |
| 脱扣等级 | 10A, 10, 20, 30 | Class 10 for normal motors, 20/30 for high-inertia loads.IEC 60947-4-1 |
| 额定绝缘电压 | 690 V | Maximum voltage for insulation design.IEC 60947-4-1 |
| 额定工作电压 | 690 V AC | Maximum operating voltage.IEC 60947-4-1 |
| 频率 | 50/60 Hz | Compatible with standard power supplies. |
| 脱扣电流精度 | ±5 % | Accuracy of trip current at ambient temperature.IEC 60947-4-1 |
| 环境温度 | -25–55 °C | Operating range; outside this may affect accuracy.IEC 60947-4-1 |
| 防护等级 | IP20 | Finger protection; higher IP available with enclosure.IEC 60529 |
| 复位方式 | Manual/Auto | Manual for safety, auto for remote operation. |
| 电气寿命 | 100000 操作 | Number of operations under rated conditions.IEC 60947-4-1 |
| 机械寿命 | 1000000 操作 | Number of mechanical operations without maintenance.IEC 60947-4-1 |
| 重量 | 0.1–2.5 kg | Depends on current rating and features. |
区间为行业参考值,供询价时圈定范围用,不构成供应商承诺。下单前请向法人制造商核实每一项数值与标准。
诱因 → 失效模式 → 工程缓解
| pressure: | 不适用(电气设备,无压力额定值) |
| other spec: | 电流范围:典型值0.1A至630A,电压:最高690V交流,频率:50/60Hz,防护等级:根据外壳不同为IP20至IP55 |
| temperature: | -20°C 至 +60°C(运行环境温度),-40°C 至 +85°C(储存温度) |
不是客户评论,也不是实时热度。以下维度用于前期 RFQ 准备和供应商评估。
这些分值是采购评估维度示例,不代表真实客户评分、具体国家买家反馈或实时询盘。
热式过载继电器利用双金属片或焊料锅,随电流发热并机械脱扣。电子式利用传感器和微处理器测量电流,并根据编程曲线脱扣。两者都保护电机免受过载,但电子式提供更精确和可调的保護。
根据电机的满载电流(FLA)选择。继电器的整定范围必须覆盖FLA。同时考虑负载的启动特性,选择适当的脱扣等级(如10、20、30)。所有参数需与制造商数据和电机规格核实。
脱扣等级表示继电器在过载电流(例如整定值的7.2倍)下允许的最大脱扣时间(秒)。10级在10秒内脱扣,20级在20秒内,30级在30秒内。选择允许电机启动而不误脱扣但仍能保护的等级。
主要标准是IEC 60947-4-1,涵盖低压开关设备和控制设备中的电机起动器。它定义了额定工作电流、脱扣等级、精度等参数。另外,IEC 60529涉及防护等级。务必与制造商核实合规性。
CNFX 是开放目录,不是交易平台或采购代理。工厂资料和表单用于帮助你准备直接沟通。
CNFX 制造商资料、技术分类、公开产品信息和持续合理性检查。
说明目标数量、应用场景、交期和关键技术要求,用于准备 RFQ 或供应商评估。